3
Set-up and installation
Fig. 3-4
Dimensions, top of unit – type ETS(X/H)B16P50D
Item
Designation
1
Solar inflow
2
Cold water
3
Hot water
4
Heating flow
5
Heating return flow
6
Outdoor unit water outlet
connection
Tab. 3-1
Legend for
Fig. 3-1
to
3.2

Transport and delivery

WARNING
When unfilled, the indoor unit is top-heavy and could tip
over during transport. That could put persons in danger or
damage the unit.
▪ Secure the indoor unit well, transport carefully, use the
handles.
The indoor unit is delivered on a pallet. All industrial trucks, such as
lifting trucks and forklift trucks, are suitable for transport.
Scope of delivery
▪ Indoor unit (pre-mounted),
▪ Bag of accessories (see
Fig.
3-5),
▪ Document pack.
Installer reference guide
12
Item
Designation
7
Outdoor unit water inlet
connection
8
Bivalent feed (type
ETS(X/H)B only)
9
Bivalent return (type
ETS(X/H)B only)
A
front
B
rear
Fig. 3-4
Fig. 3-5
Contents of bag of accessories
A
Handles (only required for transport)
B
Cover panel
C
Hose connecting piece for safety overflow
D
Assembly wrench
E
Ball valve
F
Flat gasket
G
O-ring
H
Cable tie
I
Securing clip
J
Venting hose
K
Drain hose cover
L
Controller rotary switch
M
Hood screws
For further accessories for the indoor unit, see price list.
3.3

Installing the heat pump

3.3.1

Selecting the installation site

The installation site of the indoor unit must meet the minimum re-
quirements below (see also
Chap.
Installation area
▪ The base must be level and smooth and have sufficient ground
load-bearing capacity of 1050 kg/m² plus safety factor. Install a
pedestal if necessary.
▪ Observe the installation dimensions (see
Heat pump (indoor unit) with integrated heat accumulator
1.2.3).
Chap.
3.1).
Daikin Altherma ETS(X/H)(B)-D