18 www.electrolux.com
3.
11.8 Frost precautions
If the appliance is installed in an area
where the temperature can be less than 0
°C, remove the remaining water from the
inlet hose and the drain pump.
Do this procedure also when you
want to do the emergency drain.
1.
Disconnect the mains plug from the
mains socket.
2.
Close the water tap.
3.
Remove the water inlet hose.
4.
Remove the drain hose from the rear
support and unhook it from sink or
spigot.

12. TROUBLESHOOTING

The start of the appliance does not occur
or it stops during operation.
First try to find a solution to the problem
(refer to the table). If not, contact the
Service.
With some problems, the acoustic signals
operate. The red indicator
and one of the indicators comes on, to
show an alarm code:
- The appliance does not fill with
water.
4.
20°
5.
Put the ends of the drain and inlet
hose in a container. Let the water
flow out of the hoses.
6.
When no more water flows, install the
inlet hose and the drain hose again.
water.
not closed correctly. Check the door!
flashes
45°
WARNING!
Make sure that the temperature is
more than 0 °C before you use
the appliance again.
The manufacturer is not responsi-
ble for damages caused by low
temperatures.
- The appliance does not drain the
- The appliance door is open or
WARNING!
Deactivate the appliance before
you do the checks.