3.5

Technical specifications

Rated voltage for logic and sensors (L1)
Voltage range L1
Rated voltage for RollerDrive (L2)
Voltage range L2
Current consumption
Protection rate
Degree of contamination
Weight
Ambient temperature in operation
Ambient temperature during transport and
storage
Max. temperature change
Max. relative humidity
Altitude of installation site
Version 2.7 (05/2021) UL
Translation of the original operating manual
24 V DC, protected extra-low
voltage (PELV)
22 to 27,5 V DC
24 V DC, protected extra-low
voltage (PELV)
22 to 27,5 V DC
Logic supply voltage L1:
MultiControl: Max. 0.2 A + connected sensors/actuators = max.
1.6 A
RollerDrive supply voltage L2:
RollerDrive rated current:
Max. 4 x 3.5 A = 14.0 A
RollerDrive starting current:
Max. 4 x 7.5 A = 30.0 A
IP54 (not UL-tested)
2
500 g (incl. base plate)
-30 °C to +40 °C (-22 °F to +104 °F)
-40 °C to +80 °C (-40 °F to +176 °F)
1 K/min, 3 h, 2 cycles
93% at +40 °C (104 °F), 14 days, non-condensating
Max. 1000 m (3280 ft)
In principle, it is possible to install the equipment at altitudes
higher than 1000 m (3280 ft). However, this may reduce the
performance values.
Product information
48 V DC, protected extra-low
voltage (PELV)
44 to 51,5 V DC
RollerDrive rated current:
Max. 4 x 1.75 A = 7.0 A
RollerDrive starting current:
Max. 4 x 3.8 A = 15.2 A