3.0 SIREN MODULE

+B
Positive battery (connected at the factory)
-B
Negative battery (connected at the factory)
+
Supply positive
-
Supply negative
AL
Alarm input. Programmable referred to positive or negative.
System status input. Programmable referred to positive or negative.
S
The standard provides that must be connected to the positive or negative pole according to
your polarisation choice.
TA
TAMPER contact support terminals (normally closed)
TA

3.1 PROGRAMMING

Siren options are programmable through a series of cutting-wire jumpers that can be identified with letters "A"
to "F".
Default programming highlighted in grey.
Jumper
Function
A, B
Sound time-out
*
Remote supply detection
C
D
Input reference
*
Alarms count
E
*
Scaffolds function
F
Cutting of the jumpers marked by an asterisk (

3.2 SOUND TIME OUT PROGRAMMING (A,B)

This function allows programming the maximum delay after which, should
the block signal go on missing, the siren automatically stops (useful
function in case of cable cutting).
The siren will generate a new alarm cycle with a following lack of the block
signal.
NOTE: The standards EN50131-4 do not allow for alarm time settings
longer than 15 minutes.
AP connector for speaker connection
*
), will imply the loss of conformity with EN50131 standards.
21/36
OPEN
CLOSED
A
B
CL.
CL.
CL.
OP.
OP.
CL.
OP.
OP.
Sound Time-out
3 minutes
6 minutes
9 minutes
15 minutes
HPA700P