4.
Commissioning
Installation in the aquarium (⌦A)
Attention! Strong magnets! Danger of crushing!
▶ Separate the magnets by twisting them. Use the recessed grip provided.
▶ Place the magnets at a distance of 30 cm away from each other.
1. With one hand, hold the pump at the desired position in the aquarium
from the inside (underneath the water level).
2. With the other hand, carefully place the magnet half with logo b onto
the glass panel at a distance from the pump (from the outside). Ensure
that the magnet does not strike against the glass panel!
3. Move the magnet half in the direction of the pump on the glass until both
magnet halves a/b lie one above the other.
Laying the mains cable (⌦B)
1. Guide the mains cable d, as required, left or right along the pump
body.
2. Fasten the cable to the corresponding bracket c.
5.
Operation
CAUTION! Material damage.
The pump must not run dry.
Switching the pump on/off
1. Insert the mains plug in the mains socket. Attention: The pump starts
immediately!
2. To turn it off, remove the mains plug from the mains socket.
Setting the flow direction (⌦C)
1. Turn the flow pump to the desired flow direction via the ball joint.
2. Fix into position by tightening the retaining ring e.