Rear panel

b
c
d
a
a GND screw terminal
Connecting the source device chassis to the GND terminal of the
unit may reduce noise in the signal.
Note
The ground is not a safety ground.
b ETHERNET jacks
Connection: RJ-45
For a wired connection to a network. Using an ETHERNET jack,
connect the unit to your router with an Ethernet cable. Using
another ETHERNET jack, you can connect the unit to another
network device (such as another XDA-QS5400) in cascade.
Notice
The unit is equipped with an Ethernet hub (Layer-2 Ethernet
switch) internally. Do not connect both ETHERNET jacks to the
same router. In that case, a routing loop might interfere with
communication of the whole network.
c IR IN/OUT jack
Connection: 3.5 mm monaural mini-plug
For connecting to an external remote control device and
inputting/outputting remote control signals. The output with pass-
through function is enabled even in standby mode.
d CUT IN : IN (SENSING)/THRU. OUT jacks
Connection: stereo RCA plug (L/R)
IN (SENSING): For connecting to a paging system or another
audio device. The audio signals cut in or fade in the playback in
each ZONE.
THRU. OUT: For outputting analog audio signals input in IN
(SENSING) jacks by pass-through function. The output is
enabled even in standby mode.
e AUX : IN/THRU. OUT jacks
Connection: stereo RCA plug (L/R)
IN: For connecting to an audio playback device such as a CD
player (analog out jack) and inputting audio signals.
You can play back music from an audio playback device when
you select "AUX" as the input source.
THRU. OUT: For outputting analog audio signals input in AUX :
IN jacks by pass-through function. The output is enabled even in
standby mode.
e
f
g
h
i
j
f PRE OUT/ZONE1– 4 jacks
Connection: stereo RCA plug (L/R)
For connecting to external power amplifiers and outputting audio
signals in ZONE1 - ZONE4.
g CHIME (CONTACT CLOSURE) 1– 4 jacks
Connection: 3.5 mm monaural mini-plug (Tip: + / Sleeve: -)
For connecting to contact closures such as door bells. When the
contact closure is closed (+ and - of the jack is shorted), the
preset chime sounds in the selected ZONE.
h TRIGGER OUT 1– 4 jacks
Connection: 3.5 mm monaural mini-plug (Tip: + / Sleeve: -)
For outputting trigger signals (DC 12 V). In general, the output
level is "High" when the unit is powered on or "Low" in standby
mode.
i NORMAL/BRIDGE switch
Selects NORMAL/BRIDGE connection of speakers. This switch
is normally set to NORMAL. Change the setting to BRIDGE only
when the speaker is used in bridge connection.
Note
Unplug the unit's power cord from the AC wall outlet before
changing the NORMAL/BRIDGE switch setting.
j SPEAKERS terminals
Connection: Euroblock connectors (supplied)
Speaker impedance: 4 Ω or over (NORMAL), 8 Ω or over
(BRIDGE)
For connecting to speakers with supplied Euroblock connectors.
k AC IN jack
For connecting the supplied power cord.
k