4. COMMISSIONING

4.1. Navigating the settings menu

Buttons
OK
• Press twice to access the settings menu
• Press once to confirm:
+ OR -
Navigating the settings list
Modifying the value of a setting
+ AND -
Exiting the settings menu

4.2. Memorising the remote controls - Fig. 11

1) Press the PROG button on the control unit for 2 seconds.
The indicator light is lit constantly.
2) Press the button on the remote control which will open the barrier.
The indicator light flashes; the remote control has been stored.
If this procedure is carried out using a channel which has already been
memorised, this channel will be cleared.
To exit programming mode without programming a remote control:
briefly press the PROG button on the control unit.

4.3. Direction of gate opening - Fig. 12

The gate should open as standard once switched on.
If the gate closes, perform the following procedure.
1) Press the OK button twice.
2) Press the - button until you access the
3) Press the OK button.
4) Press the - button until you access the
setting.
5) Press the OK button.
6) Press - to select
.
7) Press the OK button.
The direction of opening is reversed.
8) Press the + and - buttons to exit the settings menu.

4.4. Auto-programming of the gate travel - Fig. 13

Attention
The motor must be locked for auto-programming to be performed.
Danger
During the auto-programming process, obstacle detection is
inactive.
The installer must monitor the gate movements and ensure that
everyone stays a safe distance from the gate.
1) Press the OK button twice.
2) Press the - button until you access the
3) Press the OK button to start auto-programming.
The message ".... .... ...." is displayed on the interface during auto-pro-
gramming. The gate performs a varying number of cycles.
Do not interrupt the gate movements before
the interface.
During auto-programming, it is important not to block the photoelectric
cells beam and not to use the START and STOP controls or the control
interface.
4) Press the + and - buttons to exit the settings menu.
5
Function
- the parameter selection
- the parameter value
menu
setting.
is displayed on
Once auto-programming is complete, the control unit will have automat-
ically adjusted the torque values, the slowing distances and the optimum
operating times.
Warning
At the end of installation, it is essential to check that the obstacle
detection complies with appendix A of standard EN 12 453.
5. USE

5.1. Standard use of remote controls - Fig. 14

5.2. Locking/unlocking the motor - Fig. 15

Attention
Operation to be carried out with the power off.
5.3. Obstacle detection operation
When an obstacle is detected during opening or closing, the gate will stop
and reverse.

5.4. User training

All users must be trained on how to safely use this gate (standard use and
locking principle) and on the mandatory periodic checks.