Vario (P3)
The Vario flush volume adjusts the flush volume to the frequency of
use. It has two available operating modes. The Vario flushing pro-
gramme is suitable for hotels, restaurants, exhibition halls, airports
and other public facilities.
Operating Mode 1
While the urinal is used fewer than three times every 30 minutes, the
full flush is triggered after each use.
10
20
30
Operating Mode 2
If the urinal is used three or more times every 30 minutes, the third
use will trigger a reduced flush. If the urinal is not used for 120 min-
utes, then a full flush will be triggered after the next time it is used,
and Operating Mode 1 will be reactivated.
10
20
30
10 20
30 40 50 60
70 80 90 100 110 120