Victron energy Skylla-i 24/80 1+1 Mode D'emploi page 14

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

8. SPECIFICATION
Skylla-i
Input voltage (VAC)
Input voltage range (VAC)
Input voltage range (VDC)
Maximum AC input current @ 180 VAC
Frequency (Hz)
Power factor
Charge voltage 'absorption' (VDC)
Charge voltage 'float' (VDC)
Charge voltage 'storage' (VDC)
Charge current (A)
(2)
Charge current starter batt. (A)
Charge algorithm
Battery capacity (Ah)
Charge curve, Li-Ion
Temperature sensor
Can be used as power supply
Remote on-off port
CAN bus communication port
Synchronised parallel operation
Remote alarm relay
Forced cooling
Protection
Operating temp. range
Humidity (non condensing)
Material & Colour
Battery-connection
230 VAC-connection
Protection category
Weight kg (lbs)
Dimensions hxwxd in mm
(hxwxd in inches)
Safety
Emission
Immunity
1) Output voltage range 20-36V.
Can be set with rotary switch or
potentiometers.
14
24/80 (1+1)
16 A
(1)
80 A
4 A
400-800 Ah
Two RJ45 connectors, NMEA2000 protocol, galvanically isolated
DPST
AC rating: 240VAC/4A
Battery reverse polarity (fuse)
ENCLOSURE
STANDARDS
EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
2) Up to 40°C (100°F) ambient.
Output will reduce to 80% at 50°C, and to 60% at 60°C.
24/80 (3)
24/100 (1+1)
230 V
185-265 V
180-350 V
45-65 Hz
0,98
28,8 V
27,6 V
26,4 V
3 x 80 A
100 A
(max total output: 80A)
n. a.
7 stage adaptive
4 stage, with on-off control or CAN bus control
Yes
Yes
Yes (can be connected to a Li-Ion BMS)
Yes, with the CAN bus
DC rating: 4A up to 35VDC, 1A up to 60VDC
Yes
Output short circuit
-20 to 60°C (Full output current up to 40°C)
max 95%
aluminium (blue RAL 5012)
M8 bolts
screw-clamp 10mm² (AWG 7)
IP 21
7 kg (16 lbs)
405 x 250 x 150 mm
(16.0 x 9.9 x 5.9 inch)
EN 60335-1, EN 60335-2-29
EN 55014-1, EN 61000-6-3, EN 61000-3-2
24/100 (3)
20 A
3 x 100 A
(max total output: 100A)
4
n. a.
500-1000 Ah
Over temperature

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Skylla-i 24/80 3Skylla-i 24/100 1+1Skylla-i 24/100

Table des Matières