Charger source priority:
16
To configure charger
source priority
18
Alarm control
Auto return to default
19
display screen
20
Backlight control
Beeps while primary source
22
is interrupted
Overload bypass:
When enabled, the unit will
23
transfer to line mode if
overload occurs in battery
mode.
25
Record Fault code
Bulk charging voltage
26
(C.V voltage)
20
INFOSEC UPS SYSTEM - 15, rue du Moulin - 44880 Sautron - FRANCE - www.infosec-ups.com
Hot Line – Tel + 33 (0)2 40 76 15 82 - Fax + 33 (0)240 94 29 51 - hotline@infosec.fr – 08 17 AA 59 201 05
If this inverter/charger is working in Line, Standby or Fault
mode, charger source can be programmed as below:
Solar first
Solar energy will charge battery as
first priority.
Utility will charge battery only when
solar energy is not available.
Utility first
Utility will charge battery as first
priority.
Solar energy will charge battery only
when utility power is not available.
Solar and Utility
Solar energy and utility will charge
battery at the same time.
Only Solar
Solar energy will be the only charger
source no matter utility is available or
not.
If this inverter/charger is working in Battery mode or Power
saving mode, only solar energy can charge battery. Solar
energy will charge battery if it's available and sufficient.
Alarm on (default)
Alarm off
Return to default
If selected, no matter how users
display screen
switch display screen, it will
(default)
automatically return to default display
screen (Input voltage /output voltage)
after no button is pressed for 1 minute.
Stay at latest screen
If selected, the display screen will stay
at latest screen user finally switches.
Backlight on(default)
Backlight off
Alarm on (default)
Alarm off
Bypass disable
Bypass enable
(default)
Record enable
Record disable (default)
default setting: 56.4V
If self-defined is selected in program 5, this program can be
set up. Setting range is from 24.0V to 29.2V for 24V model
and 48.0V to 58.4V for 48V model. Increment of each click is
0.1V.