Dry Contact Signal - INFOSEC UPS SYSTEM G1 Solar MPPT Manuel Utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Dry Contact Signal

There is one dry contact (3A/250VAC) available on the rear panel. When program 38 is set as "disable", it
could be used to deliver signal to external device when battery voltage reaches warning level. When program
38 is set as "enable" and the unit is working in battery mode, it could be used to trigger the grounding box to
connect neutral and grounding of AC output together.
When program 38 is set as "disable" (default setting):
Unit Status
Power Off
Unit is off and no output is powered.
Output is powered from Utility.
Output
powered
from
Battery
Solar.
Power On
When program 38 is set as "enable":
Unit Status
Power Off
Unit is off.
Power On
Output is powered from Battery or Solar
13
INFOSEC UPS SYSTEM - 15, rue du Moulin - 44880 Sautron - FRANCE - www.infosec-ups.com
Hot Line – Tel + 33 (0)2 40 76 15 82 - Fax + 33 (0)240 94 29 51 - hotline@infosec.fr – 08 17 AA 59 201 05
Condition
is
Program 01
Battery voltage < Low DC warning
set
as
voltage
Utility
Battery voltage > Setting value in
or
Program 13 or battery charging
reaches floating stage
Program 01
Battery voltage < Setting value in
is
set
as
Program 12
SBU
or
Battery voltage > Setting value in
Solar first
Program 13 or battery charging
reaches floating stage
Condition
Dry contact port:
NC & C
NO & C
Close
Open
Close
Open
Open
Close
Close
Open
Open
Close
Close
Open
Dry contact port:
NC & C
NO & C
Close
Open
Open
Close