Maximum charging current:
To configure total charging
current for solar and utility
chargers.
02
(Max. charging current =
utility charging current +
solar charging current)
03
AC input voltage range
Power saving mode
04
enable/disable
05
Battery type
Auto restart when overload
06
occurs
Auto restart when over
07
temperature occurs
08
Output voltage
18
INFOSEC UPS SYSTEM - 15, rue du Moulin - 44880 Sautron - FRANCE - www.infosec-ups.com
Hot Line – Tel + 33 (0)2 40 76 15 82 - Fax + 33 (0)240 94 29 51 - hotline@infosec.fr – 08 17 AA 59 201 05
10A
20A
30A
40A
50A
60A (default)
70A
80A
90A
100A
110A
120A
130A
140A
Appliances (default)
If selected, the transfer time is within
20ms between battery mode and line
mode
UPS
If selected, the transfer time is within
10ms between battery mode and line
mode
Saving mode
If disabled, no matter connected load
disable (default)
is low or high, the on/off status of
inverter output will not be effected.
Saving mode enable
If enabled, the output of inverter will
be off when connected load is pretty
low or not detected.
AGM (default)
Flooded
If "User-Defined" is selected, battery
User-Defined
charge voltage and low DC cut-off
voltage can be set up in program 26,
27 and 29.
Restart disable
Restart enable
(default)
Restart disable
Restart enable
(default)
220V
230V (default)
240V