15 TROUBLESHOOTING
Disconnect the machine from the power supply prior to any checks performed
at the machine itself !
Trouble
Machine does not
start
Blade does not de-
pend on speed
Machine vibrates
strongly
HOLZMANN MASCHINEN GmbH
Possible cause
Machine is not connected
Fuse or contactor broken
cable loose
cable damaged
extension cord too long
Motor not suitable for existing
voltage
weak power grid
stands on uneven ground
Motor mounting is loose
blade out of balance
www.holzmann-maschinen.at
TROUBLESHOOTING
Solution
Check all electrical connections
Change fuse
activate contactor
Check cable
renew cable
Exchanges on optional extension
cable
see switch box cover for correct
wiring
Contact the electrician
new setting
tighten mounting bolts
Cause check - fix