STEINEL IS 3180-24 Consignes D'installation page 10

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

18
Troubleshooting
Problem
Cause
No power at the
breaker has tripped,
sensor
is not switched ON, or
break in wiring
short circuit
low voltage wiring to
power pack is incorrect
Lights do not
light level setting is in
switch ON
nighttime mode during
daytime operation
lamp burned out
power is off
breaker has tripped
detection zone not
correctly adjusted
power pack is in
manual on mode when
being used with a line
voltage switch
www.steinel.net
(800) 852-4343
Remedy
reset breaker, check
wiring with voltage
tester
check for proper
wiring connections
check for proper
wiring connections
adjust light level
setting
replace lamp
turn power on at
circuit breaker
reset breaker
readjust
place power pack in
the auto on mode
Troubleshooting
Problem
Cause
Lights do not
abundant heat from
switch OFF
fixture is within detection
zone and keeps lights
on as a result of
temperature change
continuous movement in
the detection zone
Lights keep
switched on light is
switching ON/OFF
within detection zone
low voltage overload on
power pack
sensor is detecting
Lights switch ON
movement outside of the
without obvious
movement
lighting zone
sensor is in pulse mode
Sensor detects
but is not connected to a
initial occupancy
but turns off in 2
time delay relay
seconds
Remedy
move sensor away
from direct view of
the fixture
readjust zone or
apply shroud
adjust detection
zone or apply
shrouds, increase
distance
reduce the
number of devices
connected to the
power pack
adjust zone or apply
shrouds
adjust sensor's time
delay or use with a
time delay relay
www.steinel.net
(800) 852-4343
19

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Is 3360-24Is 345-24

Table des Matières