Installation; Preparation Of The Hood For Installation - Elica ENT432BL Guide D'utilisation, D'entretien Et D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation

The electrical and mechanical installation must be performed by qualified
personnel.
The electrical appliance is designed to be built-in to a 2-6 cm thick worktop in the
case of TOP installations; 2.5-6 cm in the case of FLUSH installations.

Preparation of the hood for installation:

Before starting the installation:
After unpacking the product, check that it has not been damaged during
transport and in the case of problems, contact your dealer or Customer
Service, before proceeding with the installation.
Check that the product is the right size for the installation location.
Check for accessories inside the packaging (placed there for ease of
transport) such as bags containing screws, the warranty card, etc.. Remove
them and keep them safe.
Also check that there is a power socket near the installation area
Preparing the cabinet for installation:
-
The product cannot be installed above cooling appliances, dishwashers,
heaters, ovens, washing machines and dryers.
-
Cut the cabinet before inserting the hob and carefully remove shavings or
sawdust.
CAUTION! Failure to install screws and fasteners in accordance with these
instructions may result in electrical hazards.
Note: to ensure the correct installation of the product, it is recommended to tape
the pipes using an adhesive with the following characteristics:
- soft elastic PVC film, with an acrylic-based adhesive
- which complies with DIN EN 60454 regulations
- flame retardant
- excellent resistance against wear
- resistant against temperature fluctuations
- can be used in low temperatures
IMPORTANT:
use a single component adhesive sealant (S), resistant against
high temperatures up to 250°;
prior to installation, the surfaces that need to be glued must be carefully
cleaned, removing all substances that may compromise adhesion
(e.g. release agents, preservatives, grease, oils, powders, old adhesive
residue, etc.);
the sealant must be evenly distributed along the entire perimeter of the frame;
after gluing, leave to dry for approximately 24 hours.
Fig. 1b
4-Wire Cable from Home Power Supply to 4-Wire Cable
from Cooktop
IMPORTANT: Use the 4-wirw cable from home power
supply in the U.S. where local codes do not allow grounding
through homes and recreational vehicles, new construction,
and in Canada
A. Cable from home power supply
B. Black wires
C. Green or yellow-green ground wires
D. 4-wire cable from cooktop
E. Junction box
F. White wires
G. UL listed wire connector
H. red wires
I. UL listed or CSA approved conduit connector
The minimum clearance between the cooktop and wall must be at least 5 cm at the
front, at least 4 cm on the side and at least 50 cm with respect to the wall units
above.
NB = The suggested clearances are indicative: when designing the spaces,
follow the instructions of the kitchen manufacturer.
1. Connect the 2 black wires together using the UL listed wire
connectors
2. Connect the 2 red wires together using the UL listed wire
connectors
3. Connect the 2 white wires together using the UL listed wire
connectors
4. Connect the green ( or yellow-green) ground from the
cooktop cable ti the green (or yellow-green) ground wire (in
the junction box) using the UL listed wire connectors
5. Install junction box cover.3-Wire Cable from Home Power
Supply to 4-Wire Cable from Cooktop - U.S. Only
IMPORTANT: Use the 3-wir cable from home power supply
where local codes permit connecting the frame-ground
conductor to the neutral (white) junction box wire.
A. Cable from home power supply
B. Red wires
C. White wire and green (or yellow-green) wire (from cooktop)
D. 4-wire cable from cooktop
E. Junction box
F. White wires
G. UL listed wire connector
H. Black wires
I. UL listed or CSA approved conduit connector
1. Connect the 2 black wires together using the UL listed wire
connectors
2. Connect the 2 red wires together using the UL listed wire
connectors
3. Connect the green ( or yellow-green) and white cooktop
cable to the white (neutral) wire in the junction box using the
UL listed wire connectors
4. Install junction box cover.
Sequences installation - pag. 68