Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

EN
5.0 Controls
(continued...)
Operating Modes
Use (
) and (
) keys to choose from the following parameters. A function is selected when the icon is surrounded by
Function
Control Operation Setup
The unit must be programed for operation
in heating only, cooling only or heating and
cooling.
Fixed Fan Setting
F1, F2, F3 gives fan speed 1,2 or 3 respectively
with no temperature control. A1, A2, A3 gives fan
speed 1,2 or 3 respectively in heating only
if the water temperature ≥32°C.
Comfort Setting
Provides room temperature control with
automatic fan speed adjustment according to
difference between actual and set temperature.
The fan operates when water ≥32°C in heating or
≤15°C cooling.
Automatic Setting
The unit will run according to one of the 9
Auto
preset timed programs, or one of the 4 user
defined programs.
Night Set-back Setting
Provides room temperature control with
automatic fan speed adjustment according
to difference between actual and night set-back
temperature.
Holiday Function
Provides frost protection or overheat protection
during periods of absence (holiday). The control
will count down the time to "00" after which
control is resumed in Auto setting. For frost
protection the set temperature is 7°C.
For overheat the set temperature is 30°C.
Power On/Off
Turns unit on/off.
Set Clock Menu
Displays time in 12h or 24h format.
Program Menu
Provides choice from 9 pre-programed and
P
4 user defined timed programs.
Description

Adjustment

Control Operation Setup
Scroll to the Fixed Fan mode
on the (
) key.
Use (+) or (-) keys to choose from
the following:
Nod (Mode) HOt for heating.
Nod (Mode) COLd for cooling.
Nod (Mode) AUtO for heating and cooling.
Press (OK) to confirm.
Use (+) or (-) to select and press (OK) to confirm.
(Note the fan speed symbol will only appear
when the fan is running).
Press (OK) to view the set temperature.
Use (+) or (-) to adjust the required room
temperature. Default setting is 21°C in Heating.
See page 6 for program options and setup.
Press (OK) to view the actual set
temperature (Comfort or Set-back).
Press (OK) to view the set temperature.
Use (+) or (-) to adjust the required room
temperature. Default setting is 19°C in
Heating.
Select
and is
displayed.
Use the (+) and (-) to adjust the duration.
(In hours "H" if below 24H and then in days "d").
Use the (-) key to interrupt this period and
adjust the duration on "no".
Press (OK) to turn the power on or off.
Press (OK)
Use the (+) and (-) keys to set the minutes.
Press (OK)
Use the (+) and (-) keys to set the hours.
Press (OK)
Use the (+) and (-) to set the days. Press (OK).
See page 6, program mode.
.
Availability
Easy
, and then press
No
Yes
Yes
No
No
No
Yes
Yes
No
05
Full
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Iv60x100Iv60x120Iv60x140Iv60x160

Table des Matières