Filter replacement (e.g. in accordance with the filter replacement indicator F, see page 32)
Note:
Only original IDEAL filter cartridges (order from www.ideal.de) may be used. No tools are
required to replace the filter cartridge.
1.
4.
5.
9.
8.
Note:
The air purifier automatically detects that a new IDEAL filter cartridge has been inserted
and automatically resets the filter replacement indicator.
IDEAL filter cartridge
36
2.
3.
6.
7.
10.
11.
Order no. 8741 100
CAUTION: Disconnect the mains plug!
The front panel is hooked in at the bottom in two
places, and kept shut with 4 magnets. Open the
front panel from the top and hold (1.), pivot
downwards (2.) and take off (3.).
Hold the spent filter cartridge with both hands
using the recessed grips provided and turn it
anti-clockwise
(4.).
Remove the filter cartridge (5.). Remove the
protective film from the new filter cartridge (6.).
Insert the new filter cartridge with the three tabs
in the notches provided and lock in position by
turning clockwise
Hook in the front panel at the bottom first (8.),
then pivot upwards and press shut (9.). Connect
the power cable to the device first (10.), then to
the socket (11.).
(7.).