Technical Data - Boge DS2 Manuel D'utilisation

Sécheurs frigorifiques
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
Weight
Refrigerant
R134a (Kg)
Model
(Kg)
(Kg)
DS 2
DS 4
19
0.17
DS 6
DS 9
23.5
0.20
DS 12
DS 18
26.5
0.25
DS 22
31
0.30
DS 30
35
0.36
Calibration values
DS 2-6
DS 9-30
,

8.3 TECHNICAL DATA

MIN.- MAX
Ambient Temperature
Compressed
Amb
air inlet
Temperature
During
After
transport
installation
and stockage
In
0-50°C
5-50°C
65°C
Expansion automatic valve
7-AEV
2.4 barg (+ 0.1, - 0)
2.2 barg (+ 0.1, - 0)
Minimum
Air - Side
section
Max
validated
F.L.A.[A]
Working
cable for
Pressure
electrical
connection
220/240V ±10%
Ø [mm2]
1ph/50Hz
1.41
1.86
16 bar
3 G 1.5
2.21
3.43
4.39
5.03
Fan pressure Switch
12-PV
ON: 11 bar
OFF: 7.5 bar
DS2-30
Compressed
Connections
Sound
air inlet
(Tightening
pressure level
air outlet
torque)
BSP-F
[N x m]
[dB (A)]
1/2"
50
3/4"
High temperature
safety thermostat
13-HT
80°C
50
55
93