Télécharger Imprimer la page

Whale Gulper 220 Mode D'emploi page 2

Publicité

Les langues disponibles

Les langues disponibles

7. Maintenance
To inspect or replace either the valves or the
diaphragm, disconnect electrical supply the user must
firstly remove the pump head clamping rings, this is
done by unscrewing the 2 clamping screws.
This will release the pump head, and allow easy access
to the valves & diaphragm. The diaphragm and valves
should be checked for any excessive wear, damage or
cracks, and should be replaced if necessary. If the
diaphragm needs to be replaced, undo the nut in the
centre of the diaphragm and remove the diaphragm
plate & diaphragm. Note: The centre pin may be in one
of several positions, this will not affect replacement of
the diaphragm). When replacing the diaphragm this can
be fitted either cup up or down. Replace clamping plate
making sure the rounded edge faces the diaphragm,
also ensure that the outer sealing edge of the
diaphragm is located securely in the grooves between
the body & gear housing (failure to do this will cause
the pump NOT to prime). Refit clamping rings and tight-
en screws.
8. Fault Finding
The electric motor runs but no water is pumped?
Check:
a) that inlet hose connection is airtight, free from block-
ages, and does not collapse.
b) that the shower/sink drain is not clogged.
c) that the valves in the pump are not blocked & are
seating properly in the pump head.
d) that the diaphragm has not split - replace if damaged.
The motor will not operate?
Check:
a) the isolator switch is on.
b) there is 12 volts from the battery.
c) the in-line fuse & ensure all electrical connections are
tight and free from corrosion. (If fuse has blown check
for debris in pump head and clean out if necessary
replace fuse and run pump - see previous page).
9. Service Kits
Spares Kit Part No: AK1550.
Any questions contact our service desk -
Email: support@whalepumps.com.
10. Warranty
Whale Gulper pumps are guaranteed for one year from
date of purchase. This covers defects in materials and
workmanship. If the unit proves faulty return it to your
supplier with proof of purchase date.
Munster Simms Engineering Ltd
Old Belfast Road, Bangor, Co Down, Northern Ireland, BT19 1LT
Tel: +44 (0)28 9127 0531 Fax: +44 (0)28 9146 6421
Email: info@whalepumps.com Web: www.whalepumps.com
The manufacturer retains the right to decide whether to
repair or replace the unit. The manufacturer cannot be
held responsible for claims arising from incorrect instal-
lation, unauthorised modification or misuse of the prod-
uct.
The above does not affect your statutory rights.
11. Declaration of Conformity
We herewith declare that the Gulper 220(12v and
24v) models conform to the requirements of EC, EMC
directive 89/336/EEC including amendments, and to the
following other relevant Directives, and has used the fol-
lowing harmonised standards, European and national
standards in the confirming assessment.
Other Directives
Machinery (Safety) Directive 91/386/EEC.
Standards
EN55014
EN 292 PT 1 & 2 1991
ref: sr_180.03_1210

Publicité

loading