Preparation

Remove the insulation of the battery.
Activate the learn function on the control unit.
By means of the learn function, pair the internal/tamper magnetic switch and the wired inputs to an input of the control unit.
Press the test button for the learning of the device.
If the signal is received from the control unit it will show the corresponding information. Refer to the control unit manual to
complete the learning procedure.
Once the contact learning procedure has been run, set the control unit to "Walk Test" mode, holding the contact in the
required position and press the Test button to confirm that the chosen position is within the radio range of the control unit.
Proceed with the installation after having ascertained that the contact is working in the desired position.
Mounting and installation methods
The contact must be positioned on the door frame while the magnet must be positioned on the door. If the
contact is positioned on the door and the door is opening too fast, the transmission distance may be
reduced.
The magnet must not be more than 15 mm from the contact when the door is closed.
<
N
O
T
E
>
<
N
O
T
E
>
If the contact cannot be installed on the door frame, additional opening detectors can be used
on the wired inputs (see the "How to use the terminals" section for details).
Step 1: Identify an appropriate position near the door/window where the contact is positioned.
Step 2: The contact has two rib-marks on one side which indicate the position of the magnet. The
contact may be installed straight or upside down to ensure that the rib-marks are aligned with
the magnet.
Step 3: To fit the contact:
(i)
Using the two mounting holes of the contact as a template, mark the position of the holes
in the more suitable position.
(ii)
Insert the anchor bolts if the device is fixed to plaster or bricks.
(iii) Screw the contact onto the anchor bolts.
Step 4: Position the magnet on the door using the two-sided adhesive or the screws provided. The magnet must be aligned
with the side rib-marks of the contact as shown in the
<
N
O
T
E
>
<
N
O
T
E
>
Make sure that the spring of the tamper switch makes contact against the resting surface passing through the opening
of the tamper switch.
Step 5: Test the contact by opening and closing door or window with the control unit in "Walk test" mode.
Step 6: Insert the white plugs in the two mounting holes of the contact.
Step 7: The installation is complete.
Hereby, URMET S.p.A. declares that the radio equipment type: MAGNETIC CONTACTS WITH WIRED INPUTS 1051/203 is in
compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address:
www.urmet.com.
LINK TO ACCESS THE PRODUCT TECHNICAL SHEET AND DOWNLOAD THE COMPLETE MANUAL
DIRECTIVE 2012/19/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 4 July 2012 on waste electrical and
electronic equipment (WEEE).
The symbol of the crossed-out wheeled bin on the product or on its packaging indicates that this product must not be
disposed of with your other household waste.
Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the
recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the
time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the
environment.
For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your
household waste disposal service or the shop where you purchased the product.
DS1051-036
figure.

SIMPLIFIED EU DECLARATION OF CONFORMITY

5

Publicité

Table des Matières
loading

Table des Matières