Lenze ECSEE 012 Instructions De Montage page 64

Module d'alimentation en montage sur panneau
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1
Safety instructions
Residual hazards
Device protection
The power supply module may only be driven from balanced mains
ƒ
supplies. Mains supplies with earthed phase are not permitted.
The power supply module contains electrostatic sensitive devices. The
ƒ
personnel must be free of electrostatic charge prior to assembly and
service operations.
All pluggable connection terminals must only be connected or
ƒ
disconnected when no voltage is applied!
The power terminals +UG, −UG and PE are not protected against polarity
ƒ
reversal.
When wiring, observe the polarity of the power terminals!
Observe the max. permissible mains voltage. Higher voltages will damage
ƒ
the power supply module.
Operation is not permitted
ƒ
without the use of a brake resistor.
if an internal brake resistor and an external brake resistor are used
simultaneously.
if several power supply modules are connected in parallel.
64
l
EDKCSEE040 DE/EN/FR 5.0

Publicité

Table des Matières
loading

Table des Matières