Troubleshooting Guide - EINHELL GC-SP 5511 IF Instructions D'origine

Masquer les pouces Voir aussi pour GC-SP 5511 IF:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24

11. Troubleshooting guide

Faults
The equipment
does not start
The equipment
does not pump
The equipment
does not cut out
Insuffi cient pumping
rate
The equipment swit-
ches off after briefl y
running
Anl_GC-SP_5511_IF_SPK1.indb 19
Anl_GC-SP_5511_IF_SPK1.indb 19
GB
Cause
- Power supply not connected
- Floating switch does trigger
- Intake sieve clogged
- Discharge hose kinked
- Floating switch cannot sink
- Intake sieve clogged
- Performance reduced due to heavi-
ly contaminated and abrasive water
impurities
- Motor circuit-breaker switches the
equipment off due to excessive wa-
ter contamination
- Water temperature too high; motor
circuit-breaker switches the equip-
ment off
- 19 -
Remedy
- Check power supply
- Cleaning the switch unit (8)
- Clean intake sieve with water jet
- Unkink the hose
- Cleaning the switch unit (8)
- Clean intake sieve
- Clean equipment and replace wear
parts
- Unplug power plug and clean
equipment and shaft
- Ensure that maximum permissible
water temperature (35 °C) is not
exceeded
06.04.2017 13:38:26
06.04.2017 13:38:26

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

41.704.63

Table des Matières