9. Technical annexes (English)
9. Technical annexes
9.1 Spare Parts
Reference
CAR-CO2
SPA27-005
SPA3X-024
SPA3X-003
VER-SM29
FIL-013
ELE-SM3
Problem
The machine
•
The plug is not connected
does not switch
The switch has not been
•
on
switched to 'on'
Main fuse is not working
•
The heating
Faulty heating element
•
platenn does
•
Problem with the main board
not heat up
Temperature set too low
•
The heating
•
Problem with the probe of
element over-
electronic board
heats
The timer does
Disabled or faulty cylinder
•
not count down
sensor
Problem with the electronic
•
board
The press head
The buttons are not working
•
does not lower
•
Leaking cylinder
Too low pressure on air sup-
•
ply
The press head
Faulty solenoid control valve
•
does not come
Leaking cylinder
•
up
The press head
The timer is not counting
•
stays down
down
after pressing
Description
ELECTRICAL PARTS
CONTROL BOARD
MICA HEATING ELEMENT 400x500 2500W
TEMPERATURE PROBE
FUSE 5 x 20 mm T 16 A 250 V
PNEUMATIC PARTS
CYLINDER Ø100 C50
AIR FILTER
SOLENOID CONTROL VALVE 5/2 G1/8 12V
Possible cause
Solution
•
Check the connection to the electric mains
and if the machine is plugged in
Press the main switch to 'on
•
The fuse is located in the fuse holder next to
•
the power cord connector.
Check the connections and the condition of
•
the wiring
Remove the heating element
•
Check the on-screen messages and refer to
•
the section error messages, page 9
•
Check de messages on the LCD screen,
page 9
Contact your supplier
•
Check the connections
•
•
Check the on-screen messages and refer to
the section error messages, page 9
Check the connections
•
•
Check the seals and all connections, contact
your supplier
Check the valve couplings, contact your
•
supplier for replacement
Check that the air supplied is above 3 bar
•
Check the valve couplings, contact your
•
supplier for replacement
Check the seals and all connections, contact
•
your supplier
See above
•
Quantity
1
1
1
2
1
1
1
15