Function Modes - Cardin Elettronica 800/HL2524ESB Instructions D'utilisation

Masquer les pouces Voir aussi pour 800/HL2524ESB:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

REMOTE CONTROL (fig. 10 - page 8)
The system can be remotely activated using radio control devices; to set the
two functions to channels A-B-C-D use the selection jumper "J4":
- in position "A" function 1 is selected, SEQUENTIAL COMMAND;
- in position "B" function 2 is selected, CH2 (binding posts 9, 10) only if
"J5" is in position 2.
The sequential command may be set (dip "1") to "open-block-close-block"
or "open-close".
Memory module (MM)
This is extractable, furnished with a non volatile EEPROM type memory and
contains the transmitter codes and allows you to memorise up to 300 codes.
The programmed codes are maintained in this module even during blackouts.
Before memorising the transmitters for the first time remember
to cancel the entire memory content. If the electronic card has
to be replaced due to failure, the module can be extracted from
it and inserted into the new card. Make sure that the module is
correctly inserted as shown on page 8.
Signal LED "L4" (pag. 8):
Flashing quickly:
cancels a single code
Flashing slowly:
memorises a single code
Permanently lit:
memory full.
TRANSMITTER CODE MANAGEMENT
Memorising a channel (pag. 8):
1. Press and hold down button "P2" MEMO: The LED "L4" will flash slowly.
2. At the same time activate the transmitter which is to be memorised.
3. Hold down button "P2" MEMO until LED "L4" starts to flash again.
4. Release the MEMO button: The LED will continue to flash.
5. Activate the transmitter again (same transmitter, same channel; if the
channel is different or it is a different transmitter the memorisation attempt
will abort without success).
6. End of memorisation: the LED "L4" will remain lit for 2 seconds, indicating
that the transmitter has been correctly memorised.
Notes: It is not possible to memorise a code which is already in memory: if
you attempt this, the LED will switch off when you activate the transmitter
(point 2). Only after releasing the button "P2" MEMO will you be able to
continue the memorising procedure.
If after activating the transmitter for the first time you wait for more than fifteen
seconds without activating the transmitter a second time the memorisation
attempt will abort without success.
Cancelling a channel (pag. 8):
1. Press and hold down the button "P3" DEL: the LED "L4" will flash quickly.
2. Activate the transmitter channel that is to be cancelled.
3. The LED will remain lit for 2 seconds, indicating that the transmitter has
been cancelled.
Notes: If the user that you wish to cancel is not in memory, the LED will stop
flashing; only after releasing the button "P3" will you be able to continue the
cancellation procedure.
For both the memorisation and cancellation procedures, if the button is
released before activating the transmitter the procedure will abort.
Cancelling all user codes from memory (pag. 8):
1. Keep both buttons pressed down ("P2+P3") for more than four seconds.
2. LED "L4" will remain lit during the entire cancellation time (about 8 seconds).
3. LED "L4" switches off when the cancellation procedure has terminated.
Note: When the memory is almost full the time required to search for a user
code could take up to 1 second from when the command was received. If
LED "L4" remains lit memory is completely full. To memorise a new transmit-
ter you will first have to cancel a code from memory.
Memorising ulterior channels via radio
• Memorisation can be activated by radio (without opening the receiver
container) if jumper "J3" has been inserted (fig. 10).
1. Make sure that the jumper "J3" has been inserted (fig. 10).
2. Using a transmitter, in which at least one channel button "A, B, C or D" has
already been memorised in the receiver, press the button in the transmitter
as shown in figure.
Note: all the receivers within range when the channel button is pressed
(and which have at least one of the transmitter
channel buttons memorised) will activate their
signal buzzer "B1" (fig. 10).
3. Press one of the channel buttons on the
same transmitter. The receivers which do not contain that channel code
will sound a five-second long "beep" and will then deactivate. The receiv-
ers which contain the channel code will sound a one-second long "beep"
and will enter the "programming via radio" mode.
4. Press the previously chosen channel buttons on the transmitter which
you wish to memorise; the receiver will sound 2 "beeps" of half a second
each after which the receiver will be ready to receive another code.
5. To leave the programming mode wait for 3 seconds without pressing any
buttons. The receiver will sound a five-second long "beep" and will then
exit the programming mode.
Note: When the memory is entirely occupied the buzzer will sound 10 rapid
"beeps" and will automatically leave the "programming via radio" mode.
LED "L4" will remain lit on the receiver.
The same signal is given each time you try to enter "programming via radio"
when the memory is full.
CONNECTING THE ANTENNA
Connect an ANS400 tuned antenna using a coaxial cable RG58 (impedance
50Ω) with a maximum length of 15 m.

FUNCTION MODES

1) Automatic
Selected by enabling automatic reclosing (dip "2" in position "ON"). When
the door is completely closed the opening command will start a complete
cycle which will end with automatic reclosing.
Automatic reclosing starts after the programmed pause period has elapsed
when the opening cycle has been completed or straight away after the
intervention of a photoelectric cell (the intervention of a photoelectric cell
causes the pause time to be reset).
During the pause time the symbol
the blocking button during this period will stop automatic reclosing and
consequently stop the display from flashing.
The indicator light remains lit until the closing manoeuvre has terminated.
Note: the courtesy light switches on each time a movement command is
given (both via cable or via radio) and switches off 30 seconds after the
manoeuvre has been completed (only if jumper "J5" is in position "1", fig. 10).
2) Semiautomatic
Selected by deactivating automatic reclosing (dip "2" in position "OFF").
Work cycle control using separate opening and closing commands. When
the door has reached the completely open position the system will wait until
it receives a closing command either via an external control button or via
radio control, before completing the cycle.
The indicator light remains lit until the closing manoeuvre has terminated.
3) Manual manoeuvring with released motors
Releasing the motor the gate can be moved by hand; in this stage the pro-
grammer controls the position of the gate leaves.
22
will flash on the display and pressing

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

800/hl1824esb800/hlcf1800/hlcf18

Table des Matières