4. Installation
Connect the supply voltage to the input 10...24V DC and the SUPPLY LED will turn on.
Attention: Take care of the technical data and of the supply polarity.
Programming transmitters:
Briefly press LEARN/ERASE button until the LED beside the button is activated. This indicates the receivers
learn mode.
On the transmitter press any button or activate any input by keeping a distance of at least 1m. The LED starts
flashing when the transmitters radio code is stored.
After a period of about 30s the learn mode is left automatically. If you want to stop the learn mode
immediately, just disconnect the SHR-12 X4 shortly from its supply.
The receiver module may learn up to 60 different transmitter codes.
Check for error free operation of the receiver by pressing the transmitter buttons desired. The state of each
relay is indicated by appropriated control LEDs.
Delete all transmitter codes:
Press and hold the push button LEARN/ERASE for a minimum of 5 s until the control LED starts flashing and
all stored data are deleted.
If you are sure that all functions are properly choosed you may start wiring of the relay contacts.
All connections must comply with local regulations and standards, including VDE0100, VDE0700,
VDE0550/0551, VDE0711 and VDE0860. Only solid core cable is to be used for connection, since
stress relief is not provided on the product terminal connection block. As per DIN 0700 / IEC 335 / EN 60335,
no protective earth cable terminal is provided.
According to regulations, this product must only be installed by a qualified electrician. If in doubt seek
professional help before attempting to install. Incorrect Installation can damage the product and connected
devices and increase the risk of electric shock, damaged contacts or fire hazard.
Attention. Extreme danger!
When opening the product, live components may be touched. Isolate SHR-12 X4 from the
mains power supply before opening. Ensure that all connected devices and components are also
disconnected from the mains-power supply.
5. Technical Data
Supply voltage
Current consumption: Stand By 20 mA / 4 relays activated <200 mA
Outputs:
Ambient temperature: -20°C to +65°C
Dimensions:
:
10...24 V DC (abs. max. 26V)
4 isolated switch over contacts ( 230V AC / 10A, 30V DC / 5 A )
130mm x 85mm x 37mm
- 7 -