Operation - Qlima PGF 1211 Manuel D'utilisation

Masquer les pouces Voir aussi pour PGF 1211:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 48
man_PGF 1211 ('18) V6.indd 69
Step 5: Pic. 9
Step 6: Pic. 10
Step 7: Pic. 11

OPERATION

Connect the gas hose to the gas connector.
Please note:
-
The gas hose is NOT included with the heater. Hose must be purchased sepa-
rately
-
Minimum / Maximum length gas hose: 60-80 cm
-
Screw connection (France G1/2) is fitted as standard
-
Hoses 8-13 mm. can be fitted as well. When required: use the multi coun-
try connector (Pic. 13) supplied. Fitting of the multi country connector is
described in the separate manual supplied in with the included multi country
kit. When using the multi country connector: ALWAYS make sure to use hose
clamps!
For gas hose with threaded connectors: bind 2 or more rounds of plumbing
tape around the gas pipe before connecting the gas hose for security.
Bind 2 or more rounds of Teflon plumbing tape around the gas burner inlet
connector and connect the gas pipe. Use a wrench to tighten the connection.
Connect the other end of your gas hose according to the mounting instruc-
tion as supplied with the gas hose and/or supplied with the gas regulator.
Note:
-
The gas hose is NOT included with the heater
-
The gas regulator is not included with the heater
Connect the regulator to the gas cylinder (not included) according to the
mounting instruction as supplied together with the gas regulator and/or the
gas cilinder
Put gas cylinder on the base.
WARNING! Ensure the hose does not contact any high temperature surfaces, or
it may melt and leak causing a fire. After the cylinder is placed inside the heater,
secure the cylinder with block belt tightly.
TO TURN ON THE HEATER
Check that the regulator seal is correctly fitted and able to fulfil its function.
a)
Depress and turn control knob clockwise to OFF position.
b)
Fully open gas valve.
c)
Depress control knob and turn knob counter-clockwise to IGNITE position,
then to PILOT position (you will hear 2 clicks).
d)
With the pilot light is lit, keep control knob depressed for 60 seconds.
Note:
1.
If a new tank has just been connected, please allow at least one minute or
more for the air in the gas pipeline to purge out through the pilot hole,
2.
If the pilot light has not ignited, turn heater control knob to OFF position,
4
69
14-12-18 14:06

Publicité

Table des Matières
loading

Table des Matières