3. Specifications
Specifications
Output
GB
Operating current
Settling time
Non-linearity
Accuracy
Long-term stability
Reference conditions
Temperature
Humidity
Ambient pressure
Permissible temperature ranges
Operation
Storage
Temperature error in
operating temperature range
CE conformity
Pressure equipment directive
EMC directive
10
Model MG-1
Output signal
4 ... 20 mA, 2-wire
0 ... 10 V, 3-wire
0 ... 5 V, 3-wire
1 ... 5 V, 3-wire
0.5...4.5 V ratiometric DC 5 V ± 5 %
mA
max. 10
ms
≤ 2
% of span ≤ ± 0.5 (BFSL) per IEC 61298-2
1)
% of span ≤ ± 2
% of span ≤ ± 0.3 / year
°C
15 ... 25
%
15 ... 95 non-condensing
mmHg
500 ... 800
-20 ... +70 °C
-25 ... +80 °C
% of span ≤ ± 2.0
97/23/EC
2004/108/EC, EN 61326 Emission (Group 1, Class B) and
Immunity (industrial locations)
WIKA operating instructions pressure transmitter model MG-1
Power supply U
Max. resistive load R
B
DC 8 ... 30 V
R
≤ (U
A
DC 14 ... 30 V
R
> 10 kΩ
A
DC 8 ... 30 V
R
> 5 kΩ
A
DC 8 ... 30 V
R
> 5 kΩ
A
R
> 4.5 kΩ
A
-4 ... +158 °F
-13 ... +176 °F
A
– 7 V) / 0.02 A
B