IMG STAGELINE FM-404 Mode D'emploi page 8

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
5 Maintenance
GB
For outside cleaning only use a dry, soft cloth, by no
means chemicals or water which may penetrate the
unit.
Fog machines are susceptible to clogging due to
the viscid fog fluid and the high evaporating tempera-
tures. Therefore, it is recommended to have a cleaning
fluid consisting of 80 % distilled water and 20 % vine-
gar run through the unit after approx. 40 operating
hours.
1) Switch off the fog machine and disconnect the plug
of the mains cable (5) from the mains socket.
2) Completely empty the tank.
3) Remove deposits at the output nozzle for the fog
with vinegar. (Caution: The nozzle becomes very
hot during operation and has to cool down suffi-
ciently after operation!)
4) Fill the tank with cleaning liquid as indicated.
5) It is recommended to place the fog machine so that
the fog can stream outside through an open win-
dow or door. Operate the unit with the cleaning
liquid until the tank is empty.
All rights reserved by MONACOR
be reproduced in any form or by any means for any commercial use.
8
6 Specifications
Heating power: . . . . . . . 400 W
Heating-up time after
setting into operation: . . approx. 4 minutes
Tank capacity: . . . . . . . . 0.25 litre
Fog output: . . . . . . . . . . approx. 40 m
Power supply: . . . . . . . . 230 V~/50 Hz/410 VA
Ambient temperature: . . 0 – 40 °C
Dimensions, weight: . . . 160 x 105 x 240 mm, 2.1 kg
According to the manufacturer.
Subject to technical modification.
®
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual may
3
per minute

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

38.1950

Table des Matières