Depuragua RO N02T Notice D'installation Et De Maintenance page 8

Unité d'osmose inverse domestique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MANUAL/NOTICE DÌNSTALLATION/MANUALE DI INSTALLAZIONE
(MODELS RO N02T)
1.11 Reconnect tube and screw membrane housing head.
Following change:
1.12 Plug the equipment to the power supply.
1.13 Open valve water supply (1)
1.14 Open faucet to release pressure
1.15 Let the unit produce 1 tank of water and reject it (do not drink that water)
1.16 Then you can enjoy pure water again.
(See picture 6)
8.5. System disinfection.
Your reverse osmosis system should be disinfected periodically (usually done once a year
coinciding with the change of filters) You have to disinfect 3 elements, connectors, membrane
housing and deposit.
Step 1: Prepare a disinfectant solution
Purchase a disinfectant solution to osmosis or failing to prepare it with tap water and a few
drops of food sanitizer per liter of water. (not necessary more because if you put too much you can
leave a taste in the water for a few days). For the deposit is not necessary to bleach because the
tap contains chlorine.
Step 2: Connectors disinfection
Put the connector in the disinfection solution for 30 minutes. Then clear with clean water to be
installed again
Step 3: The membrane housing disinfection
1 Open the membrane housing by unscrewing the head.
2 Remove the membrane to replace and discard the old
3 Fill the membrane housing with the solution and leave it for 30 minutes.
4 Empty the membrane housing and dry with a clean cloth.
5 Replace the new membrane and reconnect tubing.
6 Continue with the tank disinfection
Step 4: Tank disinfection:
1 Close water inlet system
2 Open the faucet up to that empty all the water in the tank.
3 Connect the water inlet directly to the tank