MANUAL/NOTICE DÌNSTALLATION/MANUALE DI INSTALLAZIONE
3. TECHNOLOGICAL PROCESS OF WATER PRODUCTION
Raw water
GAC prefilter
Membrane
Waste water
4. NAME OF COMPONENTS
1. T Fitting
2 Feed water valve
5 Inlet valve
6 Booster pump
9 RO membrane
10 Membrane housing
13 Drain restrictor
14. High pressure Switch
17 T33 post filter
18 Faucet
5. TECHNICAL SPECIFICATIONS
Voltage and frequency of input: ~ 220V / 50 Hz
Working voltage: 24 V
Pump consumption: 25W ~ 36W
Pure water output capacity: 200 liters/day approximately
Pressure tank: 12 liters (approx.)
Inlet water temperature: 5° C ~ 45° C
Input water TDS: ﹤ 1200ppm
Chlorine: ﹤ 0.2ppm
Water recovery rate: 92% ~ 99%
(Depends on the quality of the inlet water)
Pressure of inlet water: 0.1MPa ~ 0.4mpa
Water inlet validity: standard municipal water
PP Pre filter
Clean water
T33 port filter
Tank
(check image 1)
4
Preasure pump
CTO prefilter
3 PP33 filter
4 Low pressure switch
7 GAC filter
8 CTO filter
11 Check valve
12 Flush valve
15 Pressure tank
16 Ball Valve
(MODELS RO N02T)
Faucet