Window-Meanings - Agilent Technologies TV 551/701 Navigator Notice De Mode D'emploi

Table des Matières

Publicité

17
Technical Information
How to Connect the Open-Collector Inputs of the Controller

Window-Meanings

Tab. 8
N.
000
008
100
101
102
103
104
105
106
107
108
292/328
Window-Meanings
Read/Write
Datatype
R/W
L
R/W
L
R/W
L
R/W
N
R/W
N
R/W
N
R/W
L
R/W
N
R/W
L
R/W
L
R/W
N
TV 551/701 Navigator User Manual / 87-900-934-01 (P)
Description
Start/Stop (in remote mode
the window is a read only)
Remote (default) or Serial
configuration
Soft Start
(write only in Stop condition)
Set Point type
Set Point threshold (expressed
in Hz, mA or s)
Set Point delay: time
between the pump start and
the set point check (seconds)
Set Point signal activation type:
the signal can be "high level
active" or "low level active"
Set point hysteresis
(in % of threshold)
Intercooling
Active Stop
(write only in stop)
Baud rate
Admitted Values
Start = 1
Stop = 0
Remote = 1
Serial = 0
(default = 1)
YES = 1
NO = 0
0 = Frequency
1 = Current
2 = Time
(default = 0)
(default = 643)
0 to 99999
(default = 0)
0 = high level
active
1 = low level
active
(default = 0)
0 to 100
(default = 2)
0 = NO
1 = YES
0 = NO
1 = YES
600 = 0
1200 = 1
2400 = 2
4800 = 3
9600 = 4
(default = 4)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

969883296988339698835969883696988379698842 ... Afficher tout

Table des Matières