Kärcher FLEX VC 35 L MC Mode D'emploi page 16

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
on account of increased release of fine dust
particles.
Anti-static system
Static charge is deflected by providing
earthing to the connection nozzles. This
prevents the formation of sparks and cur-
rent shocks with attachments with electrical
conductivity included in the delivery.
Dry vacuum cleaning
The appliance is equipped with a fleece
bag with a locking slide, order no.
329.630 (5 pc).
Note:You can use this appliance to vacu-
um all types of dust up to dust class L. It is
statutorily necessary to use a dust collec-
tion bag (see Filter systems for order
number).
Note:The appliance is suited as industrial
vacuum cleaner and as dedusting device
for the mobile operation to take up dry, non-
combustible dusts with MAK values greater
than or equal to 1 mg/m
Caution
The flat pleated filter must must always be
in place while vacuuming.
To vacuum fine dust, you must use an
additional fleece filter bag.
Install fleece filter bag
Illustration
 Release and remove the suction head.
 Insert the fleece filter bag.
 Insert and lock the suction head.
Wet vacuum cleaning
Warning
No dusts hazardous to health should be
sucked in during wet vacuuming.
Inserting the rubber lips
Illustration
 Remove the brush strips.
 Install the rubber lips.
Note: The structured side of the rubber lips
must point outwards.
Remove the fleece filter bag
Illustration
16
.
3
EN
 Release and remove the suction head.
 Pull the fleece filter bag towards the
rear.
 Pull the locking slide up and seal the
fleece filter bag tightly when removing it.
 Dispose of the fleece filter bag accord-
ing to the local provisions.
 Insert and lock the suction head.
To suck wet dirt, first remove the fleece
filter bag.
General
Caution
The flat pleated filter must must always be
in place while vacuuming.
If wet dirt is vacuumed with the uphol-
stery or crevice nozzle or if water is
sucked up from a container it is recom-
mended to deactivate the "Filter
Dedusting" function.
If the maximum liquid level is reached
the appliance will turn off automatically.
In case of non-conductive liquids
(such as emulsion drilling fluids,
oils, and greases) the appliance is
not turned off when the container is
full. The filling level must be continu-
ously monitored and the container
must be emptied in time.
After the wet vacuuming: Clean the flat
folded filter with the filter cleaning.
Clean the electrodes with a brush.
Clean the container with a damp rag
and dry it.
Clip connection
Illustration
The suction hose is equipped with a clip
system. All C-35/C-DN-35 accessories can
be connected.
3
-

Publicité

Table des Matières
loading

Table des Matières