Introduction
Thank you for selecting Atlantic's Typhoon TA400/TA800 Air Pump. Before using this air pump
please take a moment to review this manual.
This pump is designed to pump air. The oil-free, double damping air pump system produces
a large volume of air at low watts and noise. The weather-proof gasketed outer housing cover
shields the compressor from the elements in an outdoor application. Atlantic's Typhoon Air
Pump may be used in a variety of water related applications including oxygenation of ponds
and aquariums and de-icing of outdoor ponds. To avoid an accident, do not use the pump in
any way other than as described in this manual. Please note the manufacturer cannot be
responsible for accidents arising because the product was not used as prescribed. After
reading this manual keep it as a reference in case questions arise during use.
Prior to Operation and Installation
Model No.
Unit
LPM
TA400
CFM
LPM
TA800
CFM
When the pump is delivered, first perform the following checks:
• Check for any damage to pump and power cable that may have occurred during shipping.
• Check the model number to make sure it is the product that was ordered and verify
the voltage and frequency are correct.
Caution
• DO NOT operate this product under any condition other than those for which it is specified.
Failure to observe this precaution can lead to electrical shock, electrical leakage, fire, water
leakage or other problems.
• Please only use with a power supply voltage within 110-120 volt 60 Hz.
• Always turn off power or unplug the pump prior to performing any maintenance or
placing your hands into the water.
• CAUTION:
THIS AIR PUMP IS TO BE USED IN A CIRCUIT PROTECTED BY A GROUND
FAULT CIRCUIT INTERRUPTER.
• WARNING:
RISK OF ELECTRIC SHOCK - THIS PUMP IS SUPPLIED WITH A GROUNDING
CONDUCTOR AND GROUNDING-TYPE ATTACHMENT PLUG. TO REDUCE THE RISK OF ELECTRIC
SHOCK, BE CERTAIN THAT IT IS CONNECTED ONLY TO A PROPERLY GROUNDED, GROUNDING
TYPE RECEPTACLE.

Electrical Safety

• Electrical wiring should be installed by a qualified electrician in accordance with all applicable
safety regulations. Incorrect wiring can lead to pump malfunction, electrical shock or fire.
• Air Pumps must be protected by a ground fault circuit interrupter (GFCI).
• Air Pumps must be plugged into a standard, properly grounded, three pronged outlet.

Safety Instructions

• If the pump falls into the water, do not reach for it. First unplug the air pump or disconnect
the power supply and then retrieve the pump. Let a qualified technician inspect the air pump if
immersion occurs.
ATTENTION
2
Output
Max
@1'
@2'
6.5
6
5.1
0.23
0.21
0.18
13
12
10.2
0.46
0.42
0.36
Typhoon air pumps are NOT submersible, and must be
placed in a secure area away from the water's edge.
@3'
@4'
@5'
4
2.5
1
0.14
0.09
0.04
8
5
2
0.28
0.18
0.07