Télécharger Imprimer la page

Velleman-Kit K3512 Mode D'emploi page 11

Publicité

Les langues disponibles

Les langues disponibles

Voltage drop detector active directly after switching on alarm
Voltage drop detector active 5 mins after switching on
alarm (prevents triggering by the ventilator if this is not
connected)
Ventilator with positive contact
Ventilator with negative contact
Ventilator with detector not connected
CONTROL AND ADJUSTMENT
Adjusting the voltage drop detector (if used):
Connect the alarm without activating it.
Adjust trimmer potentiometer RV1 such that the LED LD1 lights up every time the
interior lighting is switched on (through the door contact), do not make this adjustment
too sensitive otherwise false alarms will occur (clockwise = equals more sensitive)
Adjusting the shock detector:
Connect the alarm without activating it.
Ensure that the ignition lock is switched out.
Strike the window with the palm of the hand (as if a burglar).
The LED on the dashboard should normally light up every time the shock detector
detects a shock. If the LED does not light up then the shock detector must be adjusted
(turn in the + direction)
Do not set the shock sensor to too sensitive, set the detector in the minimum position
needed to protect your vehicle.
If needed a second detector can be fitted (eg in a large car).
JP3
5MIN
DIR
JP3
5MIN
DIR
JP4
NEG POS
JP4
NEG POS
JP4
NEG POS
11

Publicité

loading