Velleman HAA85BL Mode D'emploi page 7

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

G) Output activation announcer – Installer programming
Locations
Code of functions
H) User code entry mode (auto or manual) – Installer programming
Locations
Code of functions
NOTE: In single user mode, no matter the selection (auto or manual mode), the master code and the user
code MUST be set as a 4-digit number.
I) Pacifier tones (keypad acknowledgement tones) – Installer programming
Locations
Code of functions
J) Allowable time to start door propped-up alarm – Installer programming
Locations
Code of functions
K) Exit programming mode
Validation Comments
Exit programming mode and return to normal operation
7. Single User or Multi-User Mode Selection
The HAA85BL has been factory-set in single user mode with
v2 15/11/2013
Validation
Validation
Validation
Validation
0
1 to 999
HAA85BL
Door forced-open alarm is disabled
Comments
1-second notifying beep is given to notify the person
outside to open the door when the output relay is
activated with a user code or egress button. Good for a
locking device without sound such as a magnetic lock.
Notifying beep disabled and replaced by 2 short
successful code entry beeps for valid user codes
Comments
Auto entry code is selected.
code is NOT required in code entry. The user code
MUST be set in the same digit length as the master
code in auto entry mode and the code length can be 4
to 8 digits long.
Manual entry mode is selected.
user code is required in code entry. The user codes
can be 4 to 8 digits long and they are not required to
be the same length as the master code.
Comments
Pacifier tones available on the keypad
All pacifier tones are off.
Comments
No propped-up alarm
Allowable time from 1 to 999 seconds before door
propped-up alarm starts
as master code.
7
key following the user
key following the
VELLEMAN

Publicité

Table des Matières
loading

Table des Matières