Table 1.2 - Keypad Features - Rockwell Automation SP200 AC Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31
Table 1.2 – Keypad Features
1
The PROGRAM key toggles between display and
program modes. The PROGRAM LED turns on
when the drive is in program mode.
2
In display mode, the ENTER key scrolls through the
display parameters.
In program mode, this key toggles between the
parameter number and parameter value.
3
In display mode, the UP ARROW key increments
the local speed reference.
In program mode, this key increments the parameter
number or parameter value.
4
In display mode, the DOWN ARROW key
decrements the local speed reference.
In program mode, this key decrements the
parameter number or parameter value.
5
The DIRECTION key toggles the drive direction
when keypad control is selected (P-10 = 1) and
reverse is enabled (P-03 = 0).
6
The JOG key issues the jog command to the drive
while pressed when keypad control is selected
1
(P-10 = 1).
The drive will jog at the frequency
selected in P-40 (Internal/Jog Frequency).
7
The START key issues start commands to the drive
when keypad control is selected (P-10 = 1).
8
The STOP key issues stop and fault reset
commands to the drive.
9
Display - see section 1.2.
10
Status LEDs - see section 1.3.
1
For drives having software version 3.1 and earlier, the JOG key does not
function. The drive will not respond when the JOG key is pressed.
About the Remote Keypad
English
Description
1-3