Liquids pumped:
Please note:

2. Safety Instructions

Electrical safety
DANGER! Electric shock!
Risk of injury due to electric shock!
v Always unplug your pump before filling,
after operation, before troubleshooting
and before carrying out any maintenance
work.
Caution: Following (DIN VDE 0100-702), the
use of the pump is only permissible if the
pump is operated via a residual-current device
(FI switch).
The pump must be located on solid, even
ground, protected from flooding. Take care
that the pump cannot fall into water.
As an additional safety device an approved
safety switch can be used.
v Please ask your electrician for his advice.
When connecting the pump to the water supply
system, the country-specific sanitary regula-
tions must be observed to prevent water not of
drinking water quality being drawn back in.
Extension cables
Data indicated on the type plate must match
the technical data of the mains supply.
Following DIN VDE 0620 the power cable as
well as any extension cable must not have
a smaller diameter than rubber sheathed cables
described with letter symbols H07 RNF.
The GARDENA Electronic Pressure Pump can be used for
pumping rainwater, tap water and chlorinated swimming pool
water.
The GARDENA Electronic Pressure Pump is not suitable
for continuous operation (e. g. industrial applications, contin­
uous circulating operation). Corrosive, easily combustible,
aggressive or explosive liquids (such as gasoline, petroleum
or nitrothinner), saltwater and food intended for consump­
tion must not be pumped. The temperature of the liquid must
not exceed 35 °C. Before the beginning of the frost period,
the Electronic Pressure Pump must be drained and placed in
frost­proof storage (see 6. Putting into Storage).
Protect the power cable from heat, oil and sharp
edges.
v Do not use the power cable for carrying the
pump or for unplugging.
In Austria
In Austria the electrical connection must satisfy
the ÖVE-EM 42, T2 (2000)/1979 § 22 to § 2022.1.
This requires that pumps used for swimming
pools and garden ponds may only be powered
through an isolating trans former.
v Please ask your electrician for his advice.
In Switzerland
In Switzerland portable devices that are used
outdoors must be connected through a residual-
current device.
General Information
If the electronic control is defective or if the
water supply on the intake side of the pump
fails, any water remaining in the pump may
heat up, generating a risk of injuries caused
by hot water on leakage.
v Disconnect the pump from the mains
via the main circuit breaker, let the water
cool (approx. 10 – 15 min.) and secure
the water supply on the intake side before
putting into operation again.
Risk of injury due to hot water!