Precautions
Preparing for unforeseen circumstances
Be prepared for unforeseen circumstances by using a
stationary monitor, for example, in conjunction with this
unit. In addition, prepare a backup unit if necessary.
Use with electrosurgical knives and similar
devices
When operating the unit in conjunction with
electrosurgical knives and similar medical devices, the
strong electromagnetic waves or voltage generated by the
devices may distort or cause flickering in the images
displayed on this unit, or otherwise affect normal operation
of this unit. This is not a malfunction.
When operating the unit in conjunction with devices that
generate strong electromagnetic waves or voltage, verify
their impact on the unit beforehand, and move the devices
so that their impact is minimized, or discontinue operation.
Condensation
If the unit is suddenly taken from a cold to a warm location,
or if ambient temperature suddenly rises, moisture may
form on the outer surface of the unit and/or inside of the
unit. This is known as condensation. If condensation
occurs, turn off the unit and wait until the condensation
clears before operating the unit. Operating the unit while
condensation is present may damage the unit.
About the OLED panels
Due to the characteristics of the material used in the OLED
panel, permanent burn-in or reduction in brightness may
occur.
These problems are not a malfunction.
The OLED panel fitted to this unit is manufactured with
high precision technology, giving a functioning pixel ratio
of at least 99.99%. Thus a very small proportion of pixels
may be "stuck", either always off (black), always on (red,
green, or blue), or flashing. In addition, over a long period
of use, because of the physical characteristics of the
organic light-emitting diode, such "stuck" pixels may
appear spontaneously. These problems are not a
malfunction.
Be sure to read this document together with the
operating instructions for the HMI-3000MT.
16
Precautions / Specifications
Specifications
General
Power requirement
supplied from HMI-3000MT
Operating conditions
Temperature: 5 °C to 35 °C (41 °F to
95 °F)
Relative humidity: 25% to 80%
(no condensation)
Atmospheric pressure: 700 hPa to
1060 hPa
Storage/transportation conditions
Temperature: –20 °C to +60 °C (–4 °F to
+140 °F)
Relative humidity: 20% to 80%
(no condensation)
Atmospheric pressure: 700 hPa to
1060 hPa
Dimensions (width / height / depth, including maximum
protrusions)
Approx. 191 mm × 173 mm × 271 mm
(7 5 ⁄
in. × 6 7 ⁄
8
Mass
Approx. 490 g (1 lb 1.3 oz.) (excluding
connection cable)
Display resolution (horizontal / vertical)
1280 × 720
Interpupillary distance (distance between eye pupils) range
55 mm to 72 mm (2 1 ⁄
Supplied accessories
Instructions for Use (1)
Optional accessories
HMO-CA50M head mount display cable
Specifications and external appearance are subject to
change without notice for product improvement.
Medical Specifications
Protection against harmful ingress of water:
Ordinary
Degree of safety in the presence of a
flammable anesthetic mixture with air or
with oxygen or nitrous oxide:
Not suitable for use in the presence of a
flammable anesthetic mixture with air or
with oxygen or nitrous oxide
Mode of operation:
Continuous