Troubleshooting

If you experience a problem with this unit, please take a moment
to review the following information before requesting service .
Moreover, the problem might be caused by something other than
this unit . Please also check the operation of the connected units .
If this product still does not operate correctly, contact the retailer
where you purchased it .
The unit does not turn on.
e Confirm that the power cord is securely connected to both the
inlet on the back of this unit and a power outlet .
e Confirm that power is being supplied to the outlet to which
the power cord is connected by, for example, connecting
another device to it .
No sound is output from the speakers. The sound is distorted.
e In this case, turn the power off and check the connections with
the digital audio source device, the amp and the speakers .
(page 8) .
e Change the input setting to the connector that is being used
for input (page 12) .
e Set AOUT (analog output) according to the amp connection .
e Adjust the volume of the amplifier and other devices .
No sampling frequency is shown to the right of "INPUT" on the
display.
e Turn the device that is connected to the selected input con-
nector on .
e Confirm that the device is properly connected to the selected
input connector .
A beeping noise is output at a regular interval.
e If a beeping noise is output at a regular interval when the unit
is in clock sync mode, the connected device might not also be
in clock sync mode . Check the connections of the clock sync
input connectors and the clock sync setting of the connected
device .
The CLOCK indicator does not stop blinking.
e Set CLK> to OFF when not using clock sync (page 14) .
e A clock signal with which the unit cannot be synchronized
might be being input . Check the connections of the clock
input connectors and the settings of the connected device .
This unit uses a microprocessor, so noise and other exter-
nal interference could cause it to stop functioning properly.
In such a case, turn the unit off and wait about one minute
before restarting operation from the beginning.