Safety Instructions - Extel SUNPOWER 40 Guide D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 4
1

SAFETY INSTRUCTIONS

Important!
Please read the user manual thoroughly before installing or using this product.
If you install this product for other people, please give the manual or a copy to the end user
Warning:
The different elements can only be dismantled by an authorised technician. .
Safety instructions:
To safely use this system, it is essential the fitters, users and technicians follow the safety procedures described
in this manual.
Specific warnings and caution symbols are indicated on the elements if necessary
Warning:
Follow these instructions:
The only connections made should be those provided in this manual: making any incorrect connections could be
dangerous and could seriously damage the system.
In view of the risks that may arise during the installation and usage phases of the product components should be
installed in accordance with the following recommendations: Do not make any modifications of any kind to any
parts of the device unless those modifications are described in this guide. Unauthorised operation will only lead
to operating problems. The manufacturer accepts no liability for damage resulting from products that have been
modified arbitrarily.
The charge regulator is intended for use in photovoltaic systems with 12V
vented or sealed (VRLA) lead acid batteries only.
Batteries store a large amount of energy. Never short circuit a battery under all circumstances. We recommend
connecting a use slow acting type, according to the nominal regulator current) directly to the battery terminal.
Batteries can produce flammable gases. Avoid making sparks, using fire or any naked flame. Make sure that the
battery room is ventilated.
Avoid touching or short circuiting wires or terminals. Be aware that the voltages on specific terminals or wires
can be up to double the battery voltage. Use isolated tools. Stand on dry ground and keep your hands dry.
2
DESCRIPTION
1 •
40W polycrystalline pre-wired (3m) solar panel, 12V
3 •
12V /10 W LED light x2
5 •
Charge controller10A
7 •
3m cable (2 wire) x2
9 •
Voltage converter 150 W max
11 •
12V /USB 5V cigarette lighter converter
Warning: Products incompatible with 230V
3
USAGE
This kit is ideal to power several 12V
1. The charge controller adjusts itself automatically to 12V
2. Detects day and night using the PV arrary.
3. It Can control loads by one time setting control or two times setting control
GB
or 230V
appliances using the voltage provided converter
CFI EXTEL SUNPOWER 40 - 04/2011 - V1
nominal voltages, It shall be used with
2 •
Double On/Off switch*
4 •
Support of lamp x2*
6 •
3m cable (3 wire)
8 •
Battery12V/40Ah
10 •
Adapter with cigarette lighter plug
system voltage.

Publicité

Table des Matières
loading

Table des Matières