Statistics; Troubleshooting; Soft Reset; Flashtube Replacement - Elinchrom ELB 400 Manuel D'utilisation

Masquer les pouces Voir aussi pour ELB 400:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26
User Manual

STATISTICS

Check lifetime of the unit and the flashtube.
DISPLAY
OPTIONS
STATISTICS
unit life
flash count
EN
power-on cnt
You can easily check the current usage of the unit and the flashtube. Very useful for servicing or
second-hand retail.

TROUBLESHOOTING

SOFT RESET

To reset all settings to default values, push the left and right buttons at the same time and hold
for at least 1 second. The unit will reboot and will clear all working parameters.
This will not reset the counter in the "Statistics" menu.

FLASHTUBE REPLACEMENT

Flashtubes have a long life with general use however multi-flashing in long sequences can cause
overheating of the electrodes leading to premature ageing. If the flashtube is broken or cracked,
triggers only sporadically, or you notice an important colour temperature shift, it could be that the
flashtube of the Quadra head needs replacing.
PREVIOUS GENERATION BATTERIES
The ELB 400 can also work in conjunction with the older generations of batteries of the Ranger
Quadra whether they are Lead-Gel or Lithium-Ion.
7

Publicité

Table des Matières
loading

Table des Matières