Changing The Anode Rod; Safety Shut-Off - Stiebel Eltron SHC 2.5 Mode D'emploi Et Directives D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
Maintenance Instructions

12.8 Changing the anode rod

A magnesium anode is used to extend the life of the tank.
Permanent removal of this anode for any reason will void
the warranty.
Depending on conditions, the magnesium anode rod may
need to be changed approximately every two years. Galvanic
and electrolytic corrosion can destroy a tank with a spent
anode rod. Rusty water is usually an indicator of a spent
anode rod.
1. Unplug and drain the water heater (See 12.3,
"Draining the water heater", pg. 9).
2. Remove the cover (See 12.4, "Removing the cover",
pg. 9).
3. Remove the heating element (See 12.5, "Removing
the heating element", pg. 9).
4. Remove the anode rod from the dismounted heating
element holder by unscrewing.
5. Fit a new anode rod into the heating element
holder.
6. Refit all the wires and the heating element.
7. Refill the water heater with water and check for
leaks before connecting the power.
10
| SHC 2.5 / SHC 4

12.9 Safety Shut-off

WARNING:
!
NEVER LOCK THE SLIDING RESET PLUNGER.
DANGER:
WATER TEMPERATURES OVER 125 °F (52 °C) CAN
CAUSE SEVERE BURNS INSTANTLY OR DEATH FROM
SCALDING. DO NOT ATTEMPT TO RESET THE HIGH
LIMIT SWITCH WITHOUT FIRST COOLING DOWN THE
WATER INSIDE THE WATER HEATER.
12.9.1 Resetting high temperature shut-off system
1. Unplug the water heater.
2. Remove the cover (See 12.4, "Removing the cover",
pg. 9).
3. Unplug the adapter (1) from the controller shaft.
4. Press in button (2) with an appropriate tool.
5. Reassemble the adapter in the correct position.
6. Reassemble the cover of the heater and tighten.
7. Reassemble the thermostat control knob.
1
2
1. Adapter
2. Button
www.stiebel-eltron-usa.com

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Shc 4

Table des Matières