You can adjust the operating time of the optics such that the system goes into alarm, depending on usage
and the location where it is installed in order to avoid false alarms.
CONFIGURATIONS:
t = 50 ms (Standard)
t = 250 ms
t = 500 ms
t = 750 ms
Fast running
TIME CHOICE:
1) Press the TEST button and perform the alignment.
2) When alignment is performed, press the TEST button to exit the alignment mode and wait for the two
consecutive beep of the buzzer.
3) If you need the standard 50 ms delay time is not necessary to continue to the next step but wait for
the confirmation BEEP at the end of the 5 seconds.
4) Re-press the TEST button within 3 seconds at a time until you hear two consecutive BEEP to
activate the mode of action 250 ms, continue to press the TEST button until you hear three
consecutive BEEP and activates the mode of action 500 ms. It's possible to obtain the means of
intervention 750ms taking further down the TEST button until the fourth consecutive BEEP.
5) To reset the time back to the first point of intervention.
Note
After installation, response time testing is required. This function allows you to match the units
sensitivity to its surroundings.
DS1033-135A

7. SETTING TIME

250ms
50ms
300ms
Normal walking
Intercept run
Pets disqualification
Wall application
Particular aplication
750ms
Slow speed