WARNING:
MISUSE or failure to follow the safety rules stated in
this instruction manual may cause serious personal
injury.
ADDITIONAL SAFETY RULES
FOR THE LASER
CAUTION:
LASER RADIATION
BEAM.
AVOID EXPOSURE - LASER RADIATION IS
EMITTED FROM APERTURE.
USE OF CONTROLS OR ADJUSTMENTS OR
PERFORMANCE OF PROCEDURES OTHER
THAN
THOSE
RESULT
IN
EXPOSURE.
Complies with 21CFR
1040.10 and 1040.11
AVOID EXPOSURE-Laser
radiation is emitted from
this aperture
CAUTION
LASER RADIATION
DO NOT STARE INTO BEAM
Maximum Output
<1mW,Wavelength:655nm
CLASS II LASER PRODUCT
009605
INSTALLATION

Bench mounting

When the tool is shipped, the handle is locked in the
lowered position by the stopper pin. Release the stopper
pin by lowering the handle slightly and pulling the
stopper pin.
009483
This tool should be bolted with four bolts to a level and
stable surface using the bolt holes provided in the tool's
base. This will help prevent tipping and possible injury.
DO NOT STARE INTO
SPECIFIED
HEREIN
HAZARDOUS
RADIATION
1. Stopper pin
1
1
USB094-1
009484

FUNCTIONAL DESCRIPTION

CAUTION:
Always be sure that the tool is switched off and
unplugged before adjusting or checking function on
the tool.
MAY
Blade guard
009485
When lowering the handle, the blade guard rises
automatically. The blade guard returns to its original
position when the cut is completed and the handle is
raised. NEVER DEFEAT OR REMOVE THE BLADE
GUARD OR THE SPRING WHICH ATTACHES TO THE
GUARD.
In the interest of your personal safety, always maintain
the blade guard in good condition. Any irregular
operation of the blade guard should be corrected
immediately. Check to assure spring loaded return
action of guard. NEVER USE THE TOOL IF THE
BLADE GUARD OR SPRING ARE DAMAGED, FAULTY
OR REMOVED. DOING SO IS HIGHLY DANGEROUS
AND CAN CAUSE SERIOUS PERSONAL INJURY.
If the see-through blade guard becomes dirty, or
sawdust adheres to it in such a way that the blade
and/or workpiece is no longer easily visible, unplug the
saw and clean the guard carefully with a damp cloth. Do
not use solvents or any petroleum-based cleaners on
the plastic guard.
If the blade guard is especially dirty and vision through
the guard is impaired, use the supplied socket wrench to
loosen the hex bolt holding the center cover. Loosen the
hex bolt by turning it counterclockwise and raise the
blade guard and center cover. With the blade guard so
6
1. Hex bolt
1. Blade guard
1