3. Technical information
o
The complete blower unit consists of a blower body, a blower, a breathing hose, a belt, a battery,
and a recharger.
Two thread filters must be attached to the blower device. The connection thread of the filters and the
breathing hose of the blower device conforms to the standard EN 148-1.
With the Proflow2, always use 2 filters of the same type and class.
o
Display and alarm buzzer.
o
Rechargeable NiMH battery 9,6V/power. Battery can be recharged 400-500 times.
o
Accessory: Instead of the battery, one can use a power supply (230 VAC), or a lighter socket cable
(12 VDC) for vehicles. In case the optional power supplies are used, the battery (snap coupling)
must be detached.
Proflow2 SC Asb 160
*) This can be achieved with a clean filter and a good battery.
Particle filter + Sari or Promask = 7 h
Particle filter + Vision = 6 h
Selection of blower-assisted breathing protector equipped with filter
(In Australia and New Zealand, see the next page for the limitations of AS/NZS 1716:2012.)
Type of protective device
Power-assisted half mask
with particle filter
Power-assisted full face
mask with particle filter
Power-assisted face shield or welding
shield with particle filter
Device with combined filter
Power-assisted half mask with gas
filter *)
TM2 gas filter class 1, 2 or 3
Power-assisted full face mask with gas
filter *)
TM3 gas filter class 1, 2 or 3
Power-assisted face shield or welding
shield with gas filter *)
TH1 gas filter class 1 or 2
TH2 gas filter class 1 or 2
TH3 gas filter class 1 or 2
*) Provided that the maximum permissible detrimental gas concentration for the gas filter is not exceeded. For
power-assisted filtering devices with gas filter, concentration must not exceed 0.05 vol.% in gas filter class 1 and
0.1 vol.% in gas filter class 2 and 0.5 vol.% in gas filter class 3.
**) If national guidelines exist: in all cases the lowest value applies.
Automatic regulation of the
air flow rate
minimum 160 l/min
Multiples of threshold
concentration **)
APF (Assigned protection factor)
BS 4275 (GB)
TM2P
20
TM3P
40
TH1P
10
TH2P
20
TH3P
40
The specified multiples of threshold value for the gas or particle filters
are given separately, but in all cases the lowest value applies.
20
40
10
20
40
Operating time on fully
charged battery
minimum 4 hours *)
BGR 190 - ZH1/701 (DE)
100
500
"Open" facepieces, such as helmets or hoods,
do not provide sufficient protection in case of
5
breakdown or inferior output of the blower.
20
Therefore, devices of class TH1 must never be
100
used against carcinogenic, very poisonous or
radioactive gases and vapours.
100
500
For devices with combined filter apply the
relevant limitations of gas and particle filters.
5
20
100
Weight of the blower
device without filters
1,650 kg