Electrical Connection; Safety Distance From Flammable Materials; Fume Exhaust Safety - Cola SABINA Manuel D'installation, D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

2.6 Electrical connection

Connect one end of the power cable to the rear socket of the stove, and the other to the wall socket.
The voltage supplied by the system must match that specified on the stove dataplate and in the technical data
section of this manual.
During stove idle periods it is advisable to remove the power cable.
- Make sure the electrical system is equipped with an earth and differential switch
in accordance with the current Regulations.
- The power cable must never touch the stove exhaust pipe.
2.7 Schema elettrico
Thermostat
Fume
probe
2.8 Emergency
Suitable fire-prevention devices should be arranged for any eventuality.
In case of a fire, proceed as follows:
- Immediately disconnect the plug.
- Extinguish the fire using suitable fire-extinguishers.
- Call the fire department immediately.
- Do not use jets of waters to extinguish the fire.
3 STOVE SAFETY

3.1 Safety distance from flammable materials

To prevent the risk of fire, stove positioning must respect a minimum distance from flammable materials, according
to that given in the technical table of the manual and on the dataplate.
Pay attention to the type of floor: for delicate and flammable materials it is advisable to use plates in steel or
toughened glass as a support base (see section 2 - Transport and Installation). In case of particularly fragile objects
such as furniture, curtains or sofas, increase the stove distance considerably.

3.2 Fume exhaust safety

In normal operation the combustion chamber is in a negative pressure, guaranteeing seal against possible smoke
leaks in the room. If a certain vacuum level is not reached or the fume exhaust outlet is blocked, the vacuum switch
detects the lack of a negative pressure inside the combustion chamber or the air flow meter detects a lack of air flow
and, through the electronic controller, switches off the auger rotation motor, signalling the anomaly with a message
on the control panel 'AL 8 NO NEG PRESS' or 'AL 9 INSUF DRAUGHT'.
Room
probe
42
System 230V
Igniter
Auger
Encoder for Fume extractor
ALT= Main safety Thermostat
ALD= vacuum switch
Baffle
Fume extractor
SABINA

Publicité

Table des Matières
loading

Table des Matières