5.3

TEMP MODE

If the remote control display shows 't', press MODE to select TEMP MODE.
The remote control display shows °C or °F in TEMP MODE.
The selected temperature is shown on the remote control display. The default
temperature for bearings is 110 °C (230 °F). If a different temperature is
desired, press UP or DOWN to adjust the temperature in steps of 1°.
It may be desirable to heat bearings to temperatures above 110 °C (230 °F)
for increased mounting time. Consult the SKF bearing specifications to
determine the maximum permitted temperature. Always ensure the bearing
does not lock due to an excessive expansion of the inner ring compared to
outer ring. See section 5.8.
If needed, press POWER to select the power level. Use the guidelines in
section 5.8 to determine the correct power setting.
Make sure the temperature probe is mounted on the bearing inner ring.
Press START/STOP to start the heater. The remote control display shows the
current temperature of the workpiece.
During heating the selected temperature can be displayed for 1 second by
pressing MODE.
When the selected temperature has been reached, the heater demagnetises
the workpiece, switches off, and generates an acoustic signal for 10 seconds
or until START/STOP is pressed.
Press START/STOP to cancel the acoustic signal and stop the heater.
Remove the workpiece with proper handling equipment.
If the workpiece remains on the heater, the heater will start again when the
temperature of the workpiece drops 10 °C (18 °F). Press START/STOP to stop
the heater and demagnetise the workpiece.
The TIH 100m is now ready to heat another workpiece with the same
settings.