Test value for low or high temperature sensors
NTC
-10 °C
0 °C
+10 °C
+20 °C
+25 °C
CERTIFICATION: EMC/2500 VAC
EB-Therm 800 is a high current unit and must therefore be
installed according to applicable regulations and be approved
by an authorised electrician.
PTC
42.5 kΩ
27.3 kΩ
18.0 kΩ
12.1 kΩ
10.0 kΩ
RoHS
+70 °C
+90 °C
+110 °C
+130 °C
+150 °C
WEEE
CB
1392 Ω
1591 Ω
1805 Ω
2023 Ω
2211 Ω
25
EN