Water Piping; Plumbing Diagram; Electrical; Electrical Connection - Waterco Ultra Guide D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION INSTRUCTIONS

Water Piping

The following piping sequence must be followed without exception: 1-pool pump 2-filter 3-
pool heat pump 4-chlorinator (when installed). Rigid PVC piping is recommended, all joints
should be glued with PVC glue. If rigid PVC is not available, you can use soft or flexible
piping with stainless steel clamps. When the piping installation is complete, operate the pool
pump and check the system for leaks. Then check the filter pressure gauge to see that
excessive pump head pressure is not indicated. NOTE: Units are designed to operate with a
minimum water circulation of 132 LPM/35 GPM.
NOTE: A bypass kit is strongly recommended and should be installed for adjustment
of water flow and ease of service.

Plumbing Diagram

POOL HEAT PUMP
Water Out
Water By-pass
Water In
Filter
IMPORTANT
MultiCyclone
Plumbing
connections
to the pool heat pump
must be made by hand
only, as it may break
the water Inlet or Outlet
From Spa From Pool
connections.
1. Either a 1/3 pound check valve or a loop MUST be installed between the pool heat pump
and any automatic chlorinator to prevent highly chlorine concentrated water from flowing
back to the pool heat pump when the pool pump is not running.
2. Units that are located below the water level of the swimming pool may require the
pressure switch to be adjusted.
This can be checked by the following method:
Switch ON the water pump and the pool heat pump
-
While the pool heat pump is running, switch OFF the water pump.
-
If the pool heat pump shuts down automatically no further action is required.
If the pool heat pump continues to run, you will need to have a qualified technician adjust the
water pressure switch (not under warranty). For further information, please contact Waterco.
Hook up
Water in Drain Water Out
Vertical Trap
SPA
POOL
Check Valve
PUMP
To Spa
Chlorinator
or Chlorine
Generator
To Pool
SPA
POOL
3 Way Valve
 
INSTALLATION INSTRUCTIONS
IMPORTANT
 

Electrical

 
To ensure your safety and ensure the adequate functioning of your pool heat pump, all
electrical work should be performed by a fully qualified and licensed electrician in
 
 
accordance with local electrical codes.
An adequate circuit breaker and copper wiring must be used. This information is available on
the name plate of the pool heat pump. It may be necessary to install a ground circuit
breaker.

Electrical Connection

Standard 60 Hz power supply
Standard 50 Hz power supply
3 phase power supply
 

Breaker Size

Please consult the name plate on the base or the side of your pool heat pump for running
amperage and required breaker size.
 

Electrical Wire Size

Please consult a qualified and licensed electrician.
 
The power cable ground must be connected to the electrical panel and to the ground
lug of the pool heat pump. An improper installation may be a potential cause of fire,
electrical shock or injury.
: 208/240 v - 60Hz-1 phase
: 208/240 v - 50Hz-1 phase
: 200/230 v - 50/60 Hz - 3 phase
: 380/420 v - 50/60 Hz - 3 phase
Pool Heat Pump