Beha-Amprobe Telaris Série Guide D'utilisation page 27

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 68
WWarning
To avoid false readings, which could lead to possible electric shock or personal injury,
replace the batteries as soon as the battery icon (
Be sure that the battery polarity is correct. A reversed battery can cause leakage.
Replace the batteries with six AA batteries. Alkaline batteries are supplied with the tester
but you can also use 1.2 V NiCd or NiMH batteries. You can also check the battery charge so
that you can replace them before they discharge.
WWarning
To avoid electrical shock or personal injury, remove the test leads and any input signals
before replacing the battery. To prevent damage or injury, install ONLY specified
replacement fuses with the amperage, voltage, and speed ratings shown in the General
Specifications section of this manual.
To replace the batteries (refer to Figure 24):
1. Press
to turn the tester off.
2. Remove the test leads from the terminals.
3. Remove the battery door by using a standard-blade screwdriver to turn the battery door
screws (3) one-quarter turn counterclockwise.
4. Press the release latch and slide the battery holder out of the tester.
5. Replace the batteries and the battery door.
Note: All stored data will be lost if the batteries are not replaced within approximately
one minute
6. Secure the door by turning the screws one-quarter turn clockwise.
Figure 24. Replacing the Batteries